Machine characteristics
4RT mold opening is the machine type with multiple
functions,suitable for the two-laype and three-layer
molds.
Double powers, double oil pumps, double motors and double oil
coolers are applied for the two axles to
work independently.
The oil system is unique in design with good stability, faster
lift-up and lift-down speed compared with
other brands when unloading/loading mold.
With the function of slow speed alignment adjusting, the adjustment
is more precise and safe.
The accurate placement of the loading/unloading mold has the 100%
placement safety design, protecting
the mold from being damaged.
The speed of mold raising and closing can be adjusted accurately
and safely.
Vulcanizing machine daily inspection and maintenance
A. routine inspection and maintenance
1) check whether the photoelectric mold closing device is sensitive and reliable;
2) check the part of the electric heating board to see whether the fixing of the electric heating board is
firm and whether the wiring is short circuit;
3) check whether there is oil leakage in motor oil pump, piping and valve;
4) check the height of fuel tank level;
5) check the flow of cooling water;
6) check for abnormal sounds in motor oil pump, piping, valve,
etc.;
7) the machine up and running, hours after the oil temperature
should be generally within 35 ° C ~ 50 ° C;
8) check whether the system pressure is normal.
B. weekly inspection and maintenance
1) if the solenoid valve is heated, check its vibration and wiring;
2) whether the fastening screw of limit switch is loose;
3) whether the pipe joint is loose;
4) whether the filter is blocked.
C. Check and maintain monthly
1) check the oil pollution of the work;
2) cleaning inside and outside the machine;
3) check screw and barrel.
D. annual inspection and maintenance
1) whether the circuit wiring is loose;
2) setting state of limit switch;
3) check the wear condition of the mechanical part, whether the
fixed screw is loose, and tighten it.
![]() |